What was found
FORWARD CARGO DOOR SURROUND STRUCTURE LOWER SILL WEB CORRODED BETWEEN BS. 440 TO BS. 492, RBL 28, ON UPPER SURFACE. / R&R SILL WEB IAW SRM & DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD CARGO DOOR SURROUND STRUCTURE LOWER SILL WEB CORRODED BETWEEN BS. 440 TO BS. 492, RBL 28, ON UPPER SURFACE. / R&R SILL WEB IAW SRM & DWG.