What was found
AFTER LIFT OFF, LANDING GEAR LEVER WOULD NOT GO INTO POSITION. USED LOCK OVERIDE, LANDING GEAR RETRACTED NORMALY. FOUND LANDING GEAR LEVER LATCH SOLENOID POPPING LATCH PRESSURE & WARN C/B. R & R LEVER LATCH SOLENOID IAW AMM 32-31-31. PERFORMED CONTROL LEVER SYSTEM TEST IAW AMM 32-31-00 AND FMC INSTALLATION TEST IAW AMM 34-61-01. NO OTHER DEFECTS NOTED AT THIS TIME.