What was found
CRACKED STRINGER AT AREA AFT OF FWD CARGO BAY BS 540 S-27R WL 151, MARKED. REMOVED CRACKED STRINGER AT BS 540-BS 500D+8' S-27R, PER SRM 53-00-03-2R-1. ACCOMPLISHED REPAIR TO STR 27R AND INSTALLED FASTENERS, PER SRM 53-00-03-2R-1; SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; DWG 143A3230; DWG 143A1215; DWG 143A0060 93114U 02NOV20.