What was found
FOUND CRACK AT RT HORIZONTAL STAB ON RIB NR 4 UPPER OUTBOARD CHORD FWD HOLE 1 EA. ACCOMPLISHED INTERN REPAIR AT RT HORIZONTAL STAB RIB NR 4 UPPER OUTBOARD CHORD FWD HOLE, PER RES-W12016363-1 REV P1 AND EA 20-155-02202 REV IR REPETITIVE INSPECTION LT TLD, SPEC LIMIT START 11/12/20. INSPECTION THRESHOLD 30 DAYS, ACTION REQUIRED: CONTACT ENGINEERING IF THE RT HORIZONTAL STABILIZER WILL BE ROBBED.