What was found
CORROSION ON FLOOR BEAM AT BS 986.5 RBL 44 WL 208.1. REMOVED CORROSION ON FLOOR BEAM AT BS 986.5 RBL 44 WL 208.1. BLEND MEASURES .4' X .6' X .030' DEEP, FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED SECTION: -1 T-CHORD AND INSTALLED NEW -1 T-CHORD, PER SRM 51-40-02 AND AS SHOWN IN EA 1-753-34127 AND DWG 147A5730 SH5.