What was found
***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AFT CARGO BAY BS 727+4' TO BS 847 LBL 22 WL 156 / CORROSION ON AFT BAY FLOOR TO SIDEWALL SUPPORT BS 727+4 TO BS 847; LBL 22; WL 156 FOUND OUT OF LIMITS DUE TO PROIMITY TO HOLES PER SRM 53-00-53-1A-2; FIG 103 DETAIL D. REMOVED SUPPORT BS 727+4 TO BS 847; LBL 22; WL156; LOCATED & DRILLED NEW SUPPORT AND INSTALLED NEW SUPPORT PER SRM 51-40-02-0G-0; DWG 146A7500; DWG 146A0061; DWG 149A8102; SRM 51-40-05-0G-0.