What was found
CABIN FLOOR PANEL 242BF HAS CRUSHED CORE ON AFT END. EVALUATED AND FOUND CRUSHED CORE LESS THAN 4 SQUARE INCHES. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-4. TAP TESTED GOOD AROUND DAMAGE. CLEANED AND PREPPED IAW SRM 53-00-50-2R-4 STEP 3 A-E. APPLIED POTTING COMPOUND IAW SRM 53-00-50-2R-4 STEP 3 F-J. CURED, REMOVED TWO INSERTS. BOND REPAIRED IAW SRM 53-00-50-2R-4 STEP 3 K-M. CURED, & INSTALLED TWO INSERTS IAW BAC 5085 STEP 8.4.2.2 & DWG 144A5810-122.