What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS807 - BS727 LBL21 WL157. ; / INSTALLED NEW FLOOR TO SIDEWALL SUPPORT IN ACB BS 727-847 LBL21 WL157 IAW SRM 51-40-02 AND DWG #146A7500.;OK TO INSTALL NEW FLOOR TO SIDEWALL SUPPORT IN AFT CARGO BAY BS807-727 LBL21 WL157;OK TO INSTALL NEW FLOOR TO SIDEWALL SUPPORT IN AFT CARGO BAY BS807-727 LBL21 WL157.;REMOVED CORROSION ON L/H FLOOR TO SIDEWALL SUPPORT BS 727-807 LBL 21 WL 157 IN NUMEROUS 1'X1' AREAS; REMOVED 0.015 FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. MICROMETER USED ID4566A S/N UNKNOWN;REMOVED OLD PART FROM PART ASSIGNED ROW;VERIFIED INSTALLED NEW FLOOR TO SIDEWALL SUPPORT IN ACB BS 727-847 LBL21 WL157 IAW SRM 51-40-02 AND DWG #146A7500.;VERIFIED VERIFIED INSTALLED NEW FLOOR TO SIDEWALL SUPPORT IN ACB BS 727-847 LBL21 WL157 IAW SRM 51-40-02 AND DWG #146A7500. <BR><BR>CARD COMPLETE;VERIFIED REMOVAL OF CORROSION ON L/H FLOOR TO SIDEWALL SUPPORT BS 727-807 LBL 21 WL 157 IN NUMEROUS 1'X1' AREAS; REMOVED 0.015 FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. MICROMETER USED ID4566A S/N UNKNOWN;LOCATED AND DRILLED NEW ACB LH FLOOR TO SIDEWALL SUPPORT BS 727 TO BS847 IAW SRM 51-40-05-0G-0 SRM 51-40-02-0G-0;LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02; 51-40-05.;REMOVED ACB LH FLOOR TO SIDEWALL SUPPORT; BS 727 TO 847 PER SRM 51-40-02-0G-0