What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS400-BS420 RBL23 WL156. ; / [01] REMOVED SIDEWALL SUPPORT ANGLE AT BS420; RBL23; WL156 IAW SRM 51-40-02<BR>REMOVED CORROSION ON SIDEWALL SUPPORT ANGLE L:1'; W:1'; D:0.010';WAS FOUND OUT OF LIMIT DUE MATERIAL LOSS EXCEED 10% OF THICKNESS IAW SRM 53-00-53-1A-2; [02] VERIFIED; [03] FABRICATED LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS400-BS420D RBL23 WL156; FROM EXTRUSION BAC1496-444#7075T62 LOT#1440365-1; IAW SRM 51-40-05-0G-0 AND DWG 143A7500; APPLIED CHEMICAL CONVERSION COATING IAW SRM 51-20-01-0G-0; OK TO PRIME.; [04] VERIFIED FABRICATED LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS400-BS420D RBL23 WL156; FROM EXTRUSION BAC1496-444#7075T62 LOT#1440365-1; IAW SRM 51-40-05-0G-0 AND DWG 143A7500;