What was found
***CORROSION*** ON FRAME DOUBLER AT AREA AFT OF ACB BS952 S-19R WL193. ; / [01] REMOVED DAMAGE FROM FRAME DOUBLER BS 952; MATERIAL LOSS MORE THAN 10% FOUND TO BE OUT OF LIMIT PER SRM 53-70-15-1A-1 FIG 103; E. <BR><BR>REMOVED FRAME DOUBLER BS 952; RBL 42 PER SRM 51-40-02.; [02] VERIFIED REMOVED DAMAGE FROM FRAME DOUBLER BS 952; MATERIAL LOSS MORE THAN 10% FOUND TO BE OUT OF LIMIT PER SRM 53-70-15-1A-1 FIG 103; E.; [03] LOCATED; DRILLED; TRIMMED; DEBURRED; APPLIED CHEMICAL CONVERSION COATING AND PRIMERED NEW FRAME DOUBLER BS 952 RBL42; USING 7075T6 .071' LOT #1459410 IAW SRM 51-40-05 AND DWG #147A8122.; [04] VERIFIED LOCATE; DRILL; TRIM; AND DEBUR; VERIFIED APPLICATION OF CHEMICAL CONVERSION COATING AND PRIMER ON NEW FRAME DOUBLER BS 952 RBL42; IAW SRM 51-40-05 AND DWG #147A8122.; [05] OK TO INSTALL FRAME DOUBLER BS 952; STR 19R; WL 193; [06] GAVE OK TO INSTALL FRAME DOUBLER BS 952; STR 19R; WL 193; [07] INSTALLED FRAME DOUBLER BS 952; STR 19R; WL 193 IAW SRM 51-40-02-0G-0; DWG# 147A8122; DWG# 147A8110.; [08] RII FUNCTION VERIFIED INSTALLED FRAME DOUBLER BS 952; STR 19R; WL 193 IAW SRM 51-40-02-0G-0; DWG# 147A8122; DWG# 147A8110.; [09] VERIFIED INSTALLED FRAME DOUBLER BS 952; STR 19R; WL 193 IAW SRM 51-40-02-0G-0; DWG# 147A8122; DWG# 147A8110.