What was found
***CORROSION*** ON INTERCOSTAL AT AFT CARGO BAY BS796 RBL6 WL153. ; / [01] REMOVED INTERCOSTAL ;BS 787-807 RBL6 WL 153 PER SRM 51-40-02-0G-0.; [02] EVALUATED CORROSION ON INTERCOSTAL; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [03] VERIFIED PART FOUND OUT OF LIMITS DUE NO SRM LIMITS ESTABLISHED; PER SRM 51-10-02; [04] LOCATED; DRILLED; AND DEBURRED NEW INTERCOSTAL ACB BS 787-807; RBL 6; WL 153 IAW SRM 51-40-05-0G-0; DWG #146A8130. OK TO INSTALL.; [05] VERIFIED LOCATED; DRILLED; AND DEBURRED NEW INTERCOSTAL ACB BS 787-807; RBL 6; WL 153 IAW SRM 51-40-05-0G-0; DWG #146A8130. OK TO INSTALL.; [06] INSTALLED NEW INTERCOSTAL ACB BS 787-807; RBL 6; WL 153 IAW SRM 51-40-02-0G-0; DWG #146A8130.; [07] VERIFIED INSTALLATION OF NEW INTERCOSTAL ACB BS 787-807; RBL 6; WL 153 IAW SRM 51-40-02-0G-0; DWG #146A8130.; [08] VERIFIED COMPLETION OF CUSTOMER CARD TTG8Q005DWQY