What was found
CRACKED INTERCOSTAL COMMON TO FLOOR PANEL 241AF BS 380-400 BL 0 WL 208 ; / [01] DAMAGE EVALUATION; NO ENTRIES FOUND ON SRM FOR CRACKS ON INTERCOSTAL BS380-400 BL0 WL208 PART TO BE REPLACED I.A.W SRM 51-10-02-0G-0 PAR 9.C; [02] REMOVED INTERCOSTAL BS 380-400; WL 208; BL0 IAW SRM 51-40-02-0G-0; [03] LOCATED AND DRILLED NEW INTERCOSTAL BS380-400 BL0 WL208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 143A5400; [04] VERIFIED LOCATE AND DRILL OF BS380-400 BL0 WL 208 INTERCOSTAL. OK TO INSTALL.; [05] INSTALLED INTERCOSTAL BS380-400 BL0 WL208 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 143A5400; [06] REMOVED AND REPLACED INTERCOSTAL BS380-400 BL0 WL208 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 143A5400; [07] VERIFIED INTERCOSTAL BS380-400 BL0 WL208 INSTALLATION I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 143A5400; [08] WORKSCOPE COMPLETE