What was found
CRACKED INTERCOSTAL COMMON TO FLOOR PANEL 231KF BS 500D-520 BL 0 WL 208 ; / [01] DAMAGE EVALUATION; NO ENTRIES FOUND ON SRM FOR CRACKS ON INTERCOSTAL BS500D-BS520 BL0 WL208 PART TO BE REPLACED I.A.W SRM 51-10-02-0G-0 PAR 9.C; [02] REMOVED INTERCOSTAL BS500D-BS520 BL0 WL208 I.A.W SRM 51-10-02-0G-0 AND SRM 51-40-02-0G-0; [03] LOCATED AND DRILLED NEW INTERCOSTAL BS500D-BS520 BL0 WL208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 143A5400; [04] VERIFIED LOCATE AND DRILL OF INTERCOSTAL AT BS500D-520 BL0. OK TO INSTALL.; [05] INSTALLED NEW INTERCOSTAL BS500D-BS520 BL0 WL208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 143A5400; [06] UPDATE REFERENCE INSTALLED NEW INTERCOSTAL BS500D-BS520 BL0 WL208 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 143A5400; [07] UPDATE REFERENCE INSTALLED NEW INTERCOSTAL BS500D-BS520 BL0 WL208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 143A5400; [08] REMOVED AND REPLACED INTERCOSTAL BS500D-BS520 BL0 WL208 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 143A5400; [09] VERIFIED INTERCOSTAL BS500D-BS520 BL0 WL208 INSTALLATION I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 143A5400; [10] COMPLETE