What was found
CORROSION ON TOP AND IN WELL OF SEAT TRACK CROWN BS 540-620 LBL 25 WL 208. ; / [01] REMOVED CORROSION ON TOP AND IN WELL OF SEAT TRACK CROWN STA 540-620; LBL 25; WL 208. MAX MATERIAL REMOVED ON TOP WAS .025' .5 BY 1'; .018' 1' BY 1' IN WELL. OUT OF LIMITS PER SRM 53-00-52-1A-1; SRM 51-10-02-0G-0. MEASURED DEPTH WITH DIAL DEPTH GAUGE ID# ATS400 S/N UNKNOWN; EXPIRES 04/2022; [02] VERIFIED CORROSION REMOVED AND OUT OF LIMITS PER SRM 53-00-52-1A-1; [03] REMOVED OUT OF LIMIT SEAT TRACK AT BS540-BS727B LBL25 WL208 IAW SRM 51-40-02-0G-0; [04] OK TO INSTALL NEW SEAT TRACK AT BS540-BS727B LBL25 WL208; [05] VERIFIED OK TO INSTALL NEW SEAT TRACK; [06] INSTALLED NEW SEAT TRACK FROM BS540-BS727B LBL25 WL208 IAW SRM 51-40-02-0G-0 DWG 144A5300; [07] VERIFIED INSTALLATION OF TRACK AT LBL 25 BS 540-727B; [08] JOB COMPLETE