What was found
CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT AFT CARGO BAY BS947 LBL8 TO RBL19 WL179. ; / [01] REMOVED ACB AFT BULKHEAD TO FLOOR SUPPORT ANGLE; BS947 LBL8 TO RBL19; WL179; IAW SRM 51-40-02-0G-0.; [02] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [03] VERIFIED CORROSION DAMAGE FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [04] LOCATED AND DRILLED NEW ACB AFT BULKHEAD TO FLOOR SUPPORT ANGLE BS 947 LBL 8 TO RBL 19 IAW SRM51-40-02-0G-0; SRM 51-40-05-0G-0.; [05] VERIFIED LOCATE AND DRILL OF NEW ACB AFT BULKHEAD TO FLOOR SUPPORT ANGLE BS 947 LBL 8 TO RBL 19 IAW SRM51-40-02-0G-0; SRM 51-40-05-0G-0; [06] OK TO INSTALL AFT BULKHEAD TO FLOOR SUPPORT; [07] VERIFIED OK TO INSTALL AFT BULKHEAD TO FLOOR SUPPORT; [08] INSTALLED ACB AFT BULKHEAD TO FLOOR SUPPORT ANGLE BS947; RBL19; WL179 PER SRM 51-40-02-0G-0 AND DWG 149A8110; DWG 149A8117; [09] ASSIGNED PART TO JOB; [10] VERIFIED THE INSTALLATION OF THE ACB AFT BULKHEAD TO FLOOR SUPPORT ANGLE BS947; RBL19; WL179; [11] VERIFIED TASK IS COMPLETE