What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727D TO 767 RBL21 WL156. ; / [01] UPDATED MEASUREMENT TABLE; [02] EVALUATED CORROSION BS 727D-767 FOUND DEEPEST MEASUREMENT AT BS 747 OF 0.020 FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING MICROMETER P/N 4566A S/N UNKOWN; [03] VERIFIED OUT OF LIMITS; [04] REMOVED ACB RH FLOOR TO SIDEWALL SUPPORT BS 727 TO 767 ; IAW SRM 51-40-02-0G-0.; [05] LOCATED AND DRILLED NEW ACB RH FLOOR TO SIDEWALL SUPPORT BS727 TO BS767; IAW SRM 51-40-05-0G-0; SRM 51-40-02-0G-0; [06] 25 UTC<BR>LOCATED AND DRILLED NEW ACB RH FLOOR TO SIDEWALL SUPPORT BS727 TO BS767; IAW SRM 51-40-05-0G-0; SRM 51-40-02-0G-0; QC VERIFIED.; [07] OK TO INSTALL ACB FLOOR TO SIDEWALL SUPPORT BS727 TO 767 RBL21 WL156.; [08] VERIFIED NUT PLATE INSTALL AND ENAMEL COATING OK TO INSTALL FLOOR TO SIDEWALL SUPPORT BS727-767.; [09] INSTALLED ACB FLOOR TO SIDEWALL SUPPORT BS727-767 RBL21 WL21 WL156 IAW SRM 51-40-02 AND DWG #146A7500.; [10] UPDATED PARTS TABLE; [11] VERIFIED THE INSTALL OF THE ACB FLOOR TO SIDEWALL SUPPORT BS727-767 RBL21 WL21 WL156 IAW SRM 51-40-02 AND DWG #146A7500; [12] VERIFIED TASK COMPLETE