What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT BS500A - BS500D RBL23 WL156. ; / [01] EVALUATED CORROSION ON FLOOR TO SIDEWALL SUPPORT FOUND 0.020 REMOVED FROM ORIG 0.040 DEEPEST LOCATION AT BS 500B+10; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DEPTH GAUGE P/N ATS 400 S/N UNKNOWN; [02] VERIFIED EVALUATED CORROSION ON FLOOR TO SIDEWALL SUPPORT FOUND 0.020 REMOVED FROM ORIG 0.040 DEEPEST LOCATION AT BS 500B+10; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DEPTH GAUGE P/N ATS 400 S/N UNKNOWN; [03] REMOVED FCB RH FLOOR TO SIDEWALL SUPPORT BS500A TO 500D IAW SRM 5140-02-0G-0; [04] LOCATED AND DRILLED NEW RH FLOOR TO SIDEWALL SUPPORT BE500A TO BS500D; IAW SRM 51-40-02-0G-0 ; SRM 51-40-05-0G-0.; [05] ADDED DRAWING 143A7500; [06] CERTIFIED STEP 5; [07] UPDATED PART REQUIREMENT; [08] VERIFIED LOCATED AND DRILLED NEW RH FLOOR TO SIDEWALL SUPPORT BE500A TO BS500D; IAW SRM 51-40-02-0G-0 ; SRM 51-40-05-0G-0.DRAWING 143A7500.; [09] OK TO INSTALL FCB RH FLOOR TO SIDEWALL SUPPORT BS500A-500D; [10] VERIFIED OK TO INSTALL FLOOR TO SIDEWALL SUPPORT BS 500A- 500D.; [11] INSTALLED FCB RH FLOOR TO SIDEWALL SUPPORT BS500A-500D; IAW SRM 51-40-02-0G-0; DWG143A7500; [12] VERIFIED INSTALLED FCB RH FLOOR TO SIDEWALL SUPPORT BS500A-500D; IAW SRM 51-40-02-0G-0; DWG143A7500.; [13] RE-VERIFIED INSTALLED FCB RH FLOOR TO SIDEWALL SUPPORT BS500A-500D; IAW SRM 51-40-02-0G-0; DWG143A7500.