What was found
ACB FLOOR TO SIDEWALL SUPPORT CORROSION; LOWER SURFACE. BS747+5.5; RBL21; WL151 ; / [01] REMOVED CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT AT BS 747+5.5'; RBL 21; WL 151 ; WORK AREA 1.0'X 1.0' X 0.015' ; REMAINING THICKNESS IS 0.025 ; ORIGINAL THICKNESS IS 0.040; FOUND TO BE OUT OF LIMITS IAW 53-00-53-1A-2 USING DEPTH GAGE ID: ATS2472; S/N UNKNOWN ;DUE 06/2022 ; PART TO BE REPAIRED BY REPLACEMENT BY CUSTOMER CARD NBR:TTG8Q006A3FD; [02] VERIFIED REMOVED CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT AT BS 747+5.5'; RBL 21; WL 151 ; WORK AREA 1.0'X 1.0' X 0.015' ; REMAINING THICKNESS IS 0.025 ; ORIGINAL THICKNESS IS 0.040; FOUND TO BE OUT OF LIMITS IAW 53-00-53-1A-2 USING DEPTH GAGE ID: ATS2472; S/N UNKNOWN ;DUE 06/2022 ; PART TO BE REPAIRED BY REPLACEMENT BY CUSTOMER CARD NBR:TTG8Q006A3FD