What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT B.S. 500A-500D; R.B.L. 24; W.L. 154. ; / REPAIR BY REPLACEMENT IAW SRM 51-10-02-0G-0.; [03] CORROSION DAMAGE WAS REMOVED IAW SRM 53-00-53-1A-2; [04] CORRECTION. CHANGED POTENTIAL CORROSION LEVEL FROM LEVEL 1 TO LEVEL 2. (OUT OF ALLOWABLE DAMAGE LIMITS); [05] VERIFIED CORRECTIVE ACTION ITEMS 1 THRU 4. OUT OF ALLOWABLE LIMITS PER SRM 53-00-53-1A-2.; [06] CALIBRATION TOOL DEPTH GAUGE<BR>ID : ATS2472<BR>S/N : UNKNOWN<BR>DUE : 06/2022; [07] LOCATED; DRILLED; AND COUNTERSANK NEW FLOOR TO SIDEWALL SUPPORT MATERIAL USING BAC1496-444#7075T62 LOT# 1466509-1 IAW SRM 51-40-05-0G-0; SRM 51-40-08-0G-0; AND DWG 143A7501 REV:-; [08] APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-20-01-0G-0 AND SOPM 20-41-02; INSTALLED FLOOR TO SIDEWALL SUPPORT AT B.S. 500A-500D; R.B.L. 24 W.L. 154 IAW SRM 51-40-02 AND DWG 143A7500 AND 143A7505