What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 344 TO BS360 AND RBL 33.5 FWD GALLEY AND LAV ; 2021-342025 / [01] OK TO INSTALL NEW WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BETWEEN BS344 TO BS360 RBL 33.5 FWD GALLEY; [02] REPLACED WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BETWEEN BS344 TO BS 360 AND RBL 33.5 FWD GALLEY IAW B737-700 SRM 51-10-02 AND DRAWING #141A5400;SHEET 33;REV-; [03] CERTIFIED RII WORK PERFORMED.