What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS312 TO BS328 AND LBL46 FWD GALLEY AND LAV ; 2021-342032 / [01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 21-JAN-22; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 21-JAN-22.; [02] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS312 TO BS328 AND LBL46 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02; 51-40-02 AND DRAWING 141A5400 SHEET 26 REV -; [03] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS312 TO BS328 AND LBL46 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02; 51-40-02 AND DRAWING 141A5400 SHEET 26 REV RII ACOMOLISHED