What was found
MAIN CABIN FWD WET AREA FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN BS-312 AND BS 328 LBL-46 ; / [01] REMOVED FLOOR STRUCTURE INTERCOSTAL AT MAIN CABIN FWD WET AREA BETWEEN STA 312- STA 328 LBL 46. REF: 51-40-02-0G-0; [02] LOCATED AND DRILLED NEW INTERCOSTAL AS PER SRM 51-40-05-0G-0.; [03] VERIFIED REMOVAL OF CRACKED INTERCOSTAL; [04] VERIFIED DRILLING OF NEW PART; [05] OK TO INSTALL NEW INTERCOSTAL; [06] INSTALLED NEW INTERCOSTAL AT MAIN CABIN FORWARD WET AREA BETWEEN STATIONS 312 AND 328 LBL 46 AS PER SRM 51-40-02-0G-0 AND DOCUMENT NUMBER 141A5400.; [07] VERIFIED INSTALLATION PER 141A5400; [08] VERIFIED INSTALLATION OF INTERCOSTAL RII; [09] JOB IS COMPLETE