What was found
MAIN CABIN FWD WET AREA FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN BS-344AND BS 328 LBL-46 ; / [01] REMOVED STRUCTURE INTERCOSTAL AT MAIN CABIN FWD WET AREA BETWEEN STA 328- STA 344 LBL 46. REF: SRM 51-40-02-0G-0; [02] LOCATED AND DRILLED NEW INTERCOSTAL AS PER SRM 51-40-05-0G-0.; [03] OK TO INSTALL; [04] INSTALLED NEW INTERCOSTAL AT MAIN CABIN FWD WET AREA STA 328 TO STA 344 LBL 46 AS PER B737-700 SRM 51-40-02-0G-0 AND DRWG # 141A5400 .; [05] VERIFIED 4