What was found
MAIN CABIN FWD WET AREA FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN BS-344 AND BS 360 BL-0 MKD 126-4 ; / [01] REMOVED FLOOR STRUCTURE INTERCOSTAL AT MAIN CABIN FWD WET AREA BETWEEN STA 344 - STA 360 BL-0. REF: SRM 51-40-01-0G-0.; [02] LOCATED AND DRILLED NEW INTERCOSTAL AS PER SRM 51-40-05-0G-0.; [03] VERIFIED STEPS 1 & 2<BR>OK TO INSTALL; [04] INTERCOSTAL INSTALLED AT MAIN CABIN FWD AREA BETWEEN STA 344 - STA 360 BL-0. REF: SRM 51-40-02-0G-0 SRM 51-40-05-0G-0. DRAWING NUMBER: 141A5400; [05] VERIFIED INSTALLATION