What was found
CRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS500B FWD SIDE LBL25 WL155. ; / [01] FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM; [02] VERIFIED OUT OF LIMITS DUE TO NO SRM LIMITS; [03] LOCATED AND DRILLED NEW ANGLE P/N: 143A7502U159 LOT: 1461470 . IAW SRM 51-40-05 AND DWG:143A7505 ID: 0005 REV:B REQUEST OK TO INSTALL; [04] UPDATED PART RECEIVING.; [05] VERIFIED CORRECTIVE ACTION 3. OK TO INSTALL.; [06] VERIFIED OK TO INSTALL.; [07] INSTALLED NEW ANGLE P/N: 143A7502U159 LOT: 1461470 . IAW SRM 51-40-02 AND DWG:143A7505 ID: 0005 REV:B; [08] VERIFIED INSTALLED NEW ANGLE P/N: 143A7502U159 LOT: 1461470 . IAW SRM 51-40-02 AND DWG:143A7505 ID: 0005 REV:B; [09] VERIFIED ALL STEPS COMPLETE.