As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT ANGLE HAS CORROSION AROUND NUTPLATE HOLES. LOCATED AT STA 500D BULKHEAD LBL 24 - RBL 24. ; / [01] CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.; [02] R/R FLOOR SUPPORT ANGLE AT STA. 500 BULKHEAD LBL 24 -RBL 24 IAW SRM 51-40-02.; [03] C/W INSPECTION.; [04] REMOVED AND REPLACED FLOOR SUPPORT ANGLE @ STA.500D BULKHEAD LBL 24-RBL 24 PER SRM 51-40-02.