What was found
R/H TRANSITION ANGLE AT STA 857-867 HAS EVIDENCE OF CORROSION. ; AFT CARGO. / [01] REMOVED CORROSION FROM RH TRANSITION ANGLE PER SRM 51-10-02 ;OUT OF LIMITS PER SRM 53-00-53-1A-2.; [02] CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-0053-1A-2.; [03] REMOVED R/H SHIELD AFT OF AFT CARGO DOOR CUTOUT; STA 847 TO STA 867 PER SRM 51-40-02.; [04] BACK DRILLED HOLES IN NEW ANGLE PER SRM 51-40-05-0G-0. ANGLE TO BE INSTALLED ON TASK CARD TTG8Q004G5BP.; [05] BACK DRILLED HOLES IN NEW ANGLE PER SRM 51-40-05-0G-0. ANGLE TO BE INSTALLED ON TASK CARD TTG8Q004G5BP.; [06] CORRECTED MEASUREMENTS; [07] CORROSION FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2. NEW ANGLE TO BE INSTALLED ON TASK CARD TTG8Q004G5BP.