What was found
R/H TRANSITION ANGLE AT STA 727C-727D HAS EVIDENCE OF CORROSION. ; AFT CARGO. / [01] CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-0053-1A-2.; [02] REMOVED AFT CARGO R/H TRANSITION ANGLE; STA 727+4 TO STA 767 PER SRM 51-40-02.; [03] BACK DRILLED HOLES IN NEW ANGLE PER SRM 51-40-05-0G-0. ANGLE TO BE INSTALLED ON TASK CARD TTG8Q004G5BP.; [04] CORRECTED MEASUREMENTS; [05] CORROSION FOUND OUT OF LIMITS PER SRM 53-00-53-1A-2. NEW ANGLE TO BE INSTALLED ON TASK CARD TTG8Q004G5BP.