What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727B - BS767 RBL21 WL156. ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT ACB P/N 146A7502-2 AREA 100' X 1' X .008' IAW SRM 51-10-02-0G-0. FOUND TO BE OUT OF LIMITS DUE TO ORIGINAL MAT. THICKNESS .040' AND REMAINNING THICKNESS .032' IAW SRM 53-00-53-1A-2 STEP 4.A.(2).<BR><BR>IT WILL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP. 9.C.<BR><BR>TOOL USED ID: IS000686 ; S/N: 67171914<BR> DATE: 03/2021 ; DUE:03/2022; [02] REMOVED FLOOR TO SIDEWALL SUPPORT AT ACB P/N 146A7502-2 FROM BS 727 + 4' TO BS 787; RBL 21; WL 156 IAW SRM 51-10-02-0G-0; [03] VERIFIED CORRECTIVE ACTION STEPS 1 AND 2; [04] RECIVED NEW FLOOR TO SIDEWALL SUPPORT ITEM 146A8127U1 LOT 1471800-1 LOCATED AND DRILLED NEW FLOOR TO SIDEWALL AT BS 727-767 RBL21 WL 156; SRM 51-40-05-OG-0 DWG 146A7500.-; [11] VERIFIED INSTALLED NEW FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS 727-767 RBL 21 WL 156;IAW SRM 51-40-02;DWG 146A7500 REV:C AND DWG 146A7502 REV:A.; [12] VERIFIED ALL STEPS COMPLETE.