What was found
RT HORIZONTAL STAB NR 4 INSPAR RIB HSS 120 FWD LOWER OTBD CORNER CRACKED. REMOVED CRACK IAW SRM 51-10-02-0G-0 & 55-10-09-2R-5 REPAIR 5. PERFORMED HFEC INSP OF CUT EDGES ON REPAIR AREA IAW NDT PART 6 51-00-00 PROCEDURE 23. NO CRACKS NOTED. PERFORMED HFEC ROTO INSP OF ALL EXISTING FASTENER HOLES WITHIN REPAIR AREA IAW NDT PART 6 51-00-00 PROCEDURE 16. NO CRACKS NOTED. ACCOMPLISHED GVI OF ALL AREAS WITHIN REPAIR AREA, NO DEFECTS NOTED IAW SRM 55-10-09-2R-5, STEP 4.F. FABRICATED ANGLE SHIM & FILLER IAW SRM 55-10-09-2R-5 REPAIR 5 & BAC 5602. LOCATED & DRILLED IAW SRM 51-40-05-0G-0. TREATED & PRIMED REPAIR PARTS IAW SRM 51-20-01 & SOPM 20-41-02. INSTALLED REPAIR IAW SRM 55-10-09-2R-5 REPAIR 5. STEP 12.