What was found
RT PASSENGER CABIN CREASE BEAM WEB SHOW SIGNS OF UPPER SURFACE CORROSION AT BS 727E+1, RBL 67.5, WL 208.1. CLEANED CORROSION ON AREA IAW SRM 53-60-13-1A-1. AFTER FURTHER INSPECTION AREA WAS FOUND TO BE CRACKED. REMOVED WEB IAW SRM 51-40-02. FABRICATED NEW WEB IAW DWG 146A5925. FABRICATED PART HEAT TREATED AND FORM OP84. TREATED AND PRIMED THE CREASE BEAM WEB IAW AMM 51-21-41-370-802, AND AMM 51-21-72-370-804. INSTALLED THE CREASE BEAM WEB IAW SRM 51-40-02, AND DWG 146A5900.