What was found
FWD CABIN LT FUSELAGE SUPPORT FRAME FLANGE HAS SMALL CRACK ABOVE L-1 DOOR CUTOUT, BS 312. TRIMMED DAMAGED AREA IAW SRM 53-10-07-2R-1, FIGURE 202. REMOVED FASTENERS AT REPAIR LOCATION IAW SRM 51-40-02-0G-0. PERFORMED HFEC ROTO ON OPEN FASTENER HOLES WITHIN REPAIR AREA IAW NDTM PART 6, 51-00-00 PROCEDURE 16. NO CRACKS. PERFORMED HFEC AT CUT OUT IAW NDTM PART 6, 51-00-00 PROCEDURE 23. NO CRACKS. PERFORMED INSURANCE CUT IAW SRM 53-10-07-2R-1. FABRICATED DOUBLER IAW SRM 53-10-07-2R-1. INSPECTED STEP 7 AND 8. REPAIR DOUBLER HEAT TREATED TO 7075-T6. APPLIED ALODINE AND PRIMER TO REPAIR AND AREA IAW SRM 51-20-01-0G-0. INSTALLED REPAIR IAW SRM 53-10-07-2R-1.