What was found
SUPPLEMENTAL INFORMATION: FWD CABIN WET AREA FLOOR INTERCOSTAL CRACKED @ LBL 45 BETWEEN STA 328 AND 344 ; / [01] REMOVED INTERCOSTAL DAMAGED IN REFERENCE. B-737 SRM 51-40-02-0G-0.; [02] LOCATED AND DRILLED HOLES IN THE NEW INTERCOSTAL IN REFERENCE B-737 SRM 51-40-02-0G-0 AT STA 328-344 LBL 45.; [03] VERIFIED NEW PART DRILL.<BR>OK TO INSTALL; [04] STAR INSTALLING HI LOCK IN REFERENCE. B737 SRM 51-40-02-0G-0.; [05] INSTALLED NEW INTERCOSTAL AT FWD WET AREA BETWEEN STA 328 AND STA 344 LBL 45 AS PER B737-700 SRM 51-40-02-0G-0 / 51-40-05-0G-0 AND DRWG # 141A5400 .; [06] VERIFIED PARTS AND MEASUREMENTS; [07] VERIFIED INSTALLATION