What was found
CORROSION AT AFT CABIN WET AREA GALLEY FLOOR SUPPORT WEB STA 1016 LBL 10. OUT OF LIMITS IAW SRM 53-70-51-1A-1. REMOVED AFT CABIN WET AREA GALLEY FLOOR SUPPORT WEB IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW AFT WET AREA FLOOR SUPPORT WEB IAW SRM=51-40-05-0G-0. PARTIALLY INSTALLED SHEAR WEB IAW SRM=51-40-05-0G-0. INSTALLED AFT CABIN WET AREA GALLEY FLOOR SUPPORT WEB IAW SRM 51-40-02-0G-0 AND DWG 147A5600 SHEET 32 REV B.