What was found
CRACK NOTED AT BS 663, LBL 09 BULKHEAD ATTACH ANGLE. REMOVED FASTENERS IN REPAIR AREA IAW SRM 51-40-02-0G-0. CUT AND REMOVED DAMAGED ATTACH ANGLE IAW SRM 57-10-10-2R-5 REPAIR 5. PERFORMED DVI OF REPAIR AREA AND UNDERLYING STRUCTURE. NO DEFECTS. COMPLETED NDT INSP FOR DAMAGE ON EDGES OF DAMAGE CUTOUT ON ANGLE IAW NDT M/M PART 6; 51-00-00; P-23, NO DEFECTS. COMPLETED NDT INSP FOR DAMAGE IN ALL CURRENTLY OPENED FASTENER HOLES COMMON TO REPAIR AREA IAW NDT M/M PART 6; 51-00-00; P-16, NO DEFECTS. FABRICATED REPAIR IAW SDR 57-10-10-2R-5 REPAIR 5. TREATED & PRIMED REPAIR AND CUT EDGES. INSTALLED REPAIR IAW SRM 57-10-10-2R-5, REPAIR 5.