As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD KEEL BEAM PANEL 192E; FWD PANEL SUPPORT STRUCTURE; HAS MULTIPLE WEAR MARKS AND CORROSION. / REMOVED CORROSION AND WEAR MARKS ON FWD KEEL BEAM SUPPORT STRUCTURE FOR PANEL 192E. VERIFIED MATERIAL LOSS. ORIGINAL THICKNESS .110; REMAINING .094 LOSS OF .016. OUT OF LIMITS IAW SRM 53-30-71-1A-1. REPAIRED IAW AAR EA 170215 IR AND SWA EA 1-A753-31316 REV IR.