What was found
SUPPLEMENTAL INFORMATION: FWD CARGO BAY BULKHEAD GUSSET IS CRACKED AT BS 500D COMMON TO STR19L ; / [01] REMOVED; LOCATED AND DRILL NEW FWD CARGO BAY BULKHEAD GUSSET AT BS 500D; STR 19L IAW SRM 51-40-02-0G-0;SRM 51-40-05-0G AND DWG 143A7902;ID: 174; REV:-; OK TO INSTALL; [02] CERTIFIED STEP 1; [03] VERIFIED CORRECTIVE ACTOIN 1; [04] OK TO INSTALL; [05] INSTALLED NEW FWD CARGO BAY BULKHEAD GUSSET AT BS 500D; STR 19L IAW SRM 51-40-02-0G-0 AND DWG 143A7902;ID: 174; REV:-; [06] CERTIFIED STEP 5 COMPLETE; [07] VERIFIED INSTALLED NEW FWD CARGO BAY BULKHEAD GUSSET AT BS 500D; STR 19L IAW SRM 51-40-02-0G-0 AND DWG 143A7902;ID: 174; REV:-