What was found
DOT#03-186 AFT PIT 2EA RH CAP STRIPS CORRODED ; / [01] REMOVED CORROSION AND VERIFIED WITH 10X MAGINIFIER ALL CORROSION REMOVED IAW SRM 51-10-02-0G-0; [02] LIMITS VERIFIED; OUT OF LIMITS DUE TO NO PUBLISHED LIMITS IN SRM<BR>BOTH CAPSTRIPS ARE SAME ORIGINAL THICKNESS AND REMAINING THICKNESS MEASUREMENTS<BR>ORIGINAL THICKNESS .063'<BR>REMAINING THICKNESS .059'<BR>AAR TOOL 36644 DATE 08-20-22; [03] VERIFIED STEPS 1 AND 2; [04] VERIFIED STEPS 1&2; [05] OK TO TREAT AND PRIME.<BR>EA ISSUED FOR REPAIR.; [06] REPAIR ACCOMPLISHED ON EA 22-125-00082-WIPI; [07] SUMMARY EA 22-125-00082 HAS BEEN APPROVED; ACTIVATED; AND ADDED AS A SUBTASK TO FAULT TTG8Q00A4LLW.; [08] REMOVED CORROSION FROM AFT CARGO COMPARTMENT AFT CAP STRIPS 2EA. AND REPAIRED IAW EA 22-125-00082; [09] ALL WORK C/W<BR>AUDIT C/W