What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 23 BS 500A+14; BS 500B+10; BS 500C+6; BS 500C+10. BS 500C+14. REMOVED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0. FABRICATED LOCATED AND DRILLED FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05-0G-0 AND DWG#143A7500; REV.-; APPLIED CHEMICAL CONVERSION COATING IAW SRM 51-20-01-0G-0; OK TO PRIME.; [07] VERIFIED CORRECTIVE ACTION 6. OKAY TO PRIME; [08] APPLIED PRIMER ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL23; FROM BS500A TO BS500D; IAW SOPM 20-41-02.; [09] VERIFIED CORRECTIVE ACTION 8; [10] COMPLETED STEPS 1 THRU 5; [11] VERIFIED COMPLETE STEPS 1 - 5.