What was found
FWD CARGO FLOOR STRUCTURE RT SIDE SHIELD AT RBL 21, BS 500-2, WL 55 CORRODED SPOT. REMOVED CORROSION IAW SRM 51-10-02-0G-0. PERFORMED UT THICKNESS INSP. ON REWORKED AREA IAW NDT PART 4 51-00-00 PROC. 3. MIN THICKNESS .031'. FOUND WITHIN LIMITS IAW SRM 53-30-15-1A-1. TREATED AND PRIMED REWORKED AREA IAW AMM 51-21-41-370-803 AND AMM 51-21-72-370-804.