What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS277 TO BS294.5 AND BL0 FWD GALLEY AND LAV ; 2022-11288 / [01] REPLACED WEB INTERCOSTAL AND FASTENERS LOCATED BETWEEN BS277 TO BS294.5 AND BL0 FWD GALLEY AND LAV. IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 141A5400.; [02] CORRECTED STEP 1; REPLACED WEB INTERCOSTAL AND FASTENERS LOCATED BETWEEN BS277 TO BS294.5 AND BL0 FWD GALLEY AND LAV. IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 141A5400. SEE INDIVIDUAL SING OFFS BELOW.; [03] TASK COMPLETED ; RII ; SEE INDIVIDUAL SING OFFS BELOW