What was found
CORROSION FLOOR STRUCTURE STRAP BETWEEN STA 1016 TO STA 1027 RBL 18 WL 208.1 AT AFT GALLEY AREA ; 2022-11330 / [01] REPLACED STRAP BETWEEN STA1016 TO STA 1027 RBL 18 WL 208.1 AT AFT GALLEY AREA. IAW B737-700 SRM 51-10-02; AND DWG NO. 147A5730; SHEET 23; REV. C. SEE INDIVIDUAL SIGN OFFS BELOW.; [02] REPLACED STRAP BETWEEN STA1016 TO STA 1027 RBL 18 WL 208.1 AT AFT GALLEY AREA. IAW B737-700 SRM 51-10-02; AND DWG NO. 147A5730; SHEET 23; REV. C. SEE INDIVIDUAL SIGN OFFS BELOW.<BR>RII