What was found
CORROSION FLOOR STRUCTURE WEB LOCATED STA 1016 BETWEEN BL 0 AND LBL 20 AT AFT GALLEY AREA ; 2022-11322 / [01] TOOL USED: TEMPERATURE CONTROLLER: P/N: 38615K71; S/N: AE-40585; DUE DATE: 07-JUL22.; [02] STEP 1 IN ERROR; CORRECTED STEP IS: TOOL USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 21-JAN-22.; [03] REPLACED WEB AND FASTENER LOCATED STA.1016 BETWEEEN BL 0 AND LBL 20 AFT GALLEY AREA. IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING 147A5600 REV B: SEE INDIVIDUAL SIGN OFFS BELOW.; [04] REPLACED WEB AND FASTENER LOCATED STA.1016 BETWEEEN BL 0 AND LBL 20 AFT GALLEY AREA. IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING 147A5600 REV B: SEE INDIVIDUAL SIGN OFFS BELOW.<BR>RII