What was found
FWD PIT STA 450-500; RBL28; THRESHOLD PLATE HAS SEVERAL AREAS OF LIGHT CORROSION; MRK'D. / REMOVED CORROSION FROM FWD PIT THRESHOLD PLATE IAW SRM 51-40-02-0G-0. VERIFIED LIMITS FOUND OUT OF LIMITS IAW SRM 53-30-15-0I-1. REMOVED AND INSTALLED NEW THRESHOLD PLATE IAW SRM 51-40-02-0G-0. VERIFIED NEW PART IAW SRM 51-30-15-0I-1 MPN 654A003-58 LOCATED AND DRILLED NEW PART IAW SRM 51-40-05-0G-0 MADE COUNTERSINK IAW SRM 51-40-08-0G-0 AND DWG 143A8330 REV B; ORIGINAL THICKNESS .045' LOSS .011' REMAINING .034. STA 450-500 RBL 28