What was found
RT MLG FORWARD TRUNNION LOCATION #1 UPPER O/B INNER FACE SHOWS EVIDENCE OF CORROSION. DOT 82-057. / AT RIGHT MLG FWD TRUNNION FITTIN G LOCATION #1 UPPER O/B INNER FACE SPOT FACED TO A DEPTH OF 0.035' AND DIAMETER OF 2.750' N SIGN OF CORROSION REMAIN PER B737-700 SRM 57-20-90-2R-2 INSTALLED SERVICABLE BUSHINGS AT #1 UPPER O/B RMLG FWD TRUNNION FITTING PER B737-700 SOPM 20-50-03 RIGHT MLG FWD TRUNNION BEARING ASSY TO BE INSTALLED ON CUSTOMER CARD 732-11-01 POS2