What was found
RT MLG FWD TRUNNION LOCATION # 3 LOWER O/B INNER FACE SHOWS EVIDENCE OF COROSION. DOT 82-059. / AT RIGHT MLG FWD TRUNNION LOCATION #3 LOWER O/B R INNER FACE; SPOT-FACED INNER SURFACE TO A DEPTH OF 0.055' AND A DIAMETER OF 2.750' NO SIGN OF ON CORROSION REMAIN PER B737-700 SRM 57-20-90-2R-2 INSTALLED SERVICEABLE BUSHINGS AT LOCATION #3 LOWER O/B INNER FACE PER B737-700 SOPM 20-50-03 RIGHT FWD MLG TRUNNION BEARING TO BE INSTALLED AT CUSTOMER CARD 732-11-01 POS2.