What was found
CRACK SUPPORT ANGLE LOCATED AT BS695 AND BL0 CENTER SECTION 2022-67700 / [01] TOOLS USED: TEMPERATURE CONTROLLERS P/N P3015GOES00000 S/N 112031023 DUE DATE 01 FEB 23; P/N P3015GOES00000 S/N 112820025 DUE DATE 01 FEB 23;[02] REPLACED SUPPORT ANGLE LOCATED AT BS695 AND BL0 CENTER SECTION. IAW SRM 51-10-02 Ï¿½TEM 9; SRM 51-40-02 AND DWG# 273A9110 SHEET 6 REV:A.<BR>SEE INDIVIDUAL SING-OFFS BELOW.;[03] REPLACED SUPPORT ANGLE LOCATED AT BS695 AND BL0 CENTER SECTION. IAW SRM 51-10-02 Ï¿½TEM 9; SRM 51-40-02 AND DWG# 273A9110 SHEET 6 REV:A. <BR>SEE INDIVIDUAL SING-OFFS BELOW. AS RII