What was found
R2 DOOR LOWER SILL INNER CHORD CREASE BEAM HAS CORROSION FROM STA 951 TO 992.8 (MKD 107-001) / [01] FOUND EXFOLIATED CORROSION ON R2 DOOR INNER CHORD FROM STA. 951 TO STA. 992.8; OUT OF LIMITS PER REF 737 SRM 53-70-15-1A-1;[02] VERIFIED STEP 1.;[03] REMOVED R2 INNER CHORD FROM STA 887+10 TO STA. 1006; PER REF 737 SRM 51-40-02-0G-0;[04] VERIFIED STEP 3;[05] LOCATED AND DRILLED NEW R2 DOOR INNER CHORD; PER REF. 737 SRM 51-40-05-0G-0;[06] VERIFIED STEP 5.;[07] OK TO TREAT AND PRIME AREA AND CHORD.;[08] TREATED AND PRIMER REF. 737 AMM 51-21-41-370-802 AND 51-21-72-370-804; AREA ON CHORD;[09] VERIFIED STEP 8.;[10] (RII) OK TO INSTALL INNER CHORD.;[11] MIXED SEALANT 0870CO80BM654SK; AT 19:00; ON 03/05/22; SQUEEZE OUT AND FASTENERS INSTALLATION VERIFICATION; DUE BY 03/09/22; AT 00:00;[12] VERIFIED STEP 11.;[13] INSTALLING R2 DOOR INNER CHORD 85% FASTENERS INSTALLED PER REF 737 SRM 51-40-02-0G-0;[14] INSTALLED R2 DOOR INNER CHORD FROM STA. 887+10 TO STA. 1006; PER REF 737 SRM 51-40-02-0G-0 AND DRAWING 147A8501 AND 147A8540;[15] VERIFIED STEPS 13 AND 14.;[16] INSTALLED R2 DOOR INNER CHORD FROM STA. 887+10 TO STA. 1006; PER REF 737 SRM 51-40-02-0G-0 AND DRAWING 147A8501 AND 147A8540;[17] VERIFIED STEP 16.