What was found
CORROSION......CABIN FWD WET AREA FLOOR @ STA 312 LBL 54 - LBL 56 WL 208.1 GRIT BAR FITTING HAS CORROSION. (18-046) / [01] REMOVED CORROSION STA312 GIRT BAR FITTING TIEDOWN REF. B737-7 SRM 51-10-02-0G-0;[02] MATERIAL REMAINING 0.025'; ORIGINAL MATERIAL. 0.080'; MATERIAL LOSS 0.055'; FOUND OUT OF LIMITS REF.B737-7 SRM53-10-51-1A-1; CLIPER B/V 165543 DUE 29JUL22;[03] REMOVED AND REPLACED FWD WET AREA GIRT BAR FITTING TIEDOWN AT STA.312 LBL554-LBL56; WL 208.1 REF. B737-7 SRM 51-40-02-0G-0 & DRW# 141A5220;[04] VERIFIED STEPS 1 TO 3.