What was found
CORROSION @ FASTENERS HOLES FWD CARGO COMPARTMENT FLOOR SUPPORT ZEE CHANNEL S-25L FROM STA 400 TO STA 500D / [01] FOUND OUT OF LIMITS; ZEE CHANNEL AT FWD CARGO COMPARTMENT L/H BETWEEN FS 396 TO FS 500D;IN REF B737-700 SRM 53-00-53-1A-2 STEP 4.A.(2);(A);FIGURE 103 DETAIL 'D';[02] FABRICATED NEW ZEE AT FWD CARGO COMPARTMENT L/H BETWEEN FS 396 TO FS 500D;IN REF B737-700 SRM 53-00-53-2R-6;[03] OK TO TREAT AND PRIME;[04] VERIFIED STEP 1 AND 2;[05] ENTER IN ERROR FUSELAGE STATION:<BR>FABRICATED NEW ZEE AT FWD CARGO COMPARTMENT L/H BETWEEN FS 396 TO FS 490;IN REF B737-700 SRM 53-00-53-2R-;[06] VERIFIED STEP 5;[07] FABRICATED NEW ZEE AT FWD CARGO COMPARTMENT L/H BETWEEN FS 500D TO FS 490;IN REF B737-700 SRM 53-00-53-2R-;[08] VERIFIED STEP 7<BR>OK TO TREAT AND PRIME;[09] TREATED AND APPLIED PRIMER AT ZEE CHANNEL AT FWD CARGO COMPARTMENT L/H BETWEEN FS 500D TO FS 490;IN REF B737-700 SRM 52-20-01-0G-0;[10] VERIFIED STEP 9.;[11] TREATED AND PRIMED FLOOR SUPPORT ZEE CHANNEL STR 25L BETWEEN FS 400 TO FS 500D;IN REF B737-700 SRM 51-20-01-0G-0;[12] FLOOR SUPPORT ZEE CHANNEL WILL BE INSTALL ON TASK CARD <BR>TTG8Q004E8RD;STEP #38;[13] FLOOR SUPPORT ZEE CHANNEL WILL BE INSTALL ON TASK CARD <BR>TTG8Q004E8RD;STEP #38